Max PVinput current 27A
Designed with 27A PV input currentcompatible to the market trend ofincreasedImp of solar panel;
Easy access
Two outputs for smart load managementThe second output can be scheduled on& offbased on setting point of battery transfer toutility;
Battery
Battery equalization function extend lifecycleReserved communication port (RS485,CAN)for BMS;
Lights
Customizable status LED ring with RGB lights;
Interface
Global cloud platform mobile APP anytimeandanywhere open APP , support power internet.
Technical Specification | VM IV PRO-MKS-4840MB | VM IV PRO-MKS-4860MD |
Rated power | 4000VA/4000W | 6000VA/6000W |
AC INPUT | ||
AC voltage | 230VAC | |
Voltage range | 170-280VAC(For Personal Computers);90-280 VAC (For Home Appliances) | |
Frequency range | 50Hz/60 Hz (Auto sensing) | |
AC OUTPUT | ||
Surge power | 8000VA | 12000VA |
Voltage regulation(Battery Mode) | 230VAC±5% | |
Rated frequency | 50/60Hz | |
Efficiency(Peak) | up to 93.5% | |
Transfer time | 10ms (For Personal Computers);20ms (For Home Appliances); | |
SOLAR CHARGER &AC CHARGER | ||
Maximum PV array open voltage(V) | 500VDC | |
Maximum PV array power | 5000W | 6000W |
MPPT voltage range(V) | 60~450VDC | |
Maximum input current | 27A | |
MPPT tracker/strings | 1 | |
Maximum solar charge current | 120A | |
Maximum AC charge current | 100A | |
Maximum charge current | 120A | |
BATTERY | ||
Battery voltage | 24VDC | 48VDC |
Floating charge voltage | 27VDC | 54VDC |
Overcharge protection | 33VDC | 63VDC |
Battery type | Lithium /Lead-acid | |
PROTECTION& FEATURE | ||
AC overcurrent | Yes | |
AC overvoltage | Yes | |
Over temperature protection | Yes | |
Smart load management | Yes | |
GENERAL PARAMTER | ||
Operation temperature | 0°C~50°C | |
Relative humidity | 0 ~95%(non-condensing) | |
Altitude | (>2,000m Derating) | |
Dimensions D x W x H (mm) | 434*311*126.5 | |
Net weight(KG) | 8.5 | 9 |
DISPLAY AND COMMUNICATION | ||
Display | Touch bottons | |
Interface | Standard:RS485,RS232,CAN ;Optional: Wifi, Bluetooth | |
Safety standard | EN/IEC 62109-1,EN/IEC 62109-2 | |
Degree of protection | IP20 |